* M250 pump is not suitable to dose chemicals that generate bubbles such as chlorine solution. The above data shows the pump max output performance at max pressure. At atmospheric pressure the pump performance must be considered bearing in mind also the loss due to the injection valve pressure I.V.P. (Injection Valve Pressure). The pump performance is +/- 10% tolerance while pump repeatability is constant.
|